Mitsubishi E Designer Software
Engineering Software Mitsubishi Electric brand software (MELSOFT) provides an integrated product suite to reduce the total cost of ownership and speed up time to market. During the engineering stage, MELSOFT products are used to design systems encompassing the entire portfolio of automation products. May 22, 2014 - From what I can tell searching online, E-Designer is the software needed, but I don't see a place I can buy or download it. I found a demo.
E Series Programming Software
The E Designer programming software makes it extremely easy to create and edit projects for the E series range of HMIs. The software's Block Manager utility provides a complete graphical overview of the project, shortening project creation times significantly.,The package comes complete with a library of ready-to-use symbols, objects and drivers for all popular ranges of PLCs.
Windows based
Drag and drop screen creation
Library of graphics
Import/Export of project data
Intuitive help menus
Complete set of E-Series HMI Electronic Manuals
Note
When using this software with a MAC 10 or MAC 40+ panel, a MAC-COM kit will be required.To program the E1000 series of HMI's, you will also require stock no. 272-359
Attribute | Value |
---|---|
Accessory Type | Software |
For Use With HMI | E1000 Series, MAC E Series |
For Use With PLC | MELSEC |
Software Version | E Designer |
Search your question against our global database of over 6000 FAQ’s
Unable to find your answer?
Search our local FAQ database here:
64bit super-scalar RISC processor is explained in catalog but isn't this a general equipment? Will it be the same if 64bitCPU is used for AGP3000 of Digital? (GOT1000) - KS00425
In order to speed up both CPU and drawing process, Mitsubishi developed special drawing chip for GOT1000 mobilizing all available resources. ..
Read moreIn order to speed up both CPU and drawing process, Mitsubishi developed special drawing chip for GOT1000 mobilizing all available resources. Therefore, we believe that GOT exceeds any other indicator in performance of both display and response.
Ab welcher GT Works3 Version werden 'Templates' unterstützt? (GOT1000) - KS04090
Ab GT Works3 Version 1.37P kann mann vorgefertigte 'Templates' auswählen, ab der Version 1.40S kann man eigene 'Templates' erstellen.
Ab welcher GT-Designer Version kann man die TCP/IP-Addresse aus GS-Registern auslesen? (GOT1000) - KS04099
Ab version 1.40S. Die TCP/IP-Addresse steht in GS198 und GS199.
Ab welcher GT-Designer Version wird der MR-J4 Servoverstärker unterstützt? (GOT1000) - KS04093
Ab welcher GT-Designer Version wird der VNC-Server unterstützt? (GOT1000) - KS04091
Ab welcher GT-Designer Version wird die Ethernet-Kommunikation zu Siemens Steuerungen unterstützt? (GOT1000) - KS04092
Ab welcher Version ist der GT-Designer auf Windows 7 (64 Bit) lauffähig? (E1000) - KS04094
Aber welcher GT-Designer Version wird das GT14 unterstützt? (GOT1000) - KS04097
Are target PLCs the same when using transparent function comparing with the direct CPU connection? (Is it possible to monitor other PLCs via MELSECNET?) (GOT1000) - KS02203
Are the communication Interfaces used with the GT15 Series compatible with the GT16 Series? (GOT1000) - KS04019
Yes - serial and network communication interfaces are fully compatible with GT16 Series.
Are the serial ports on E1000 (RS232+RS422) electrically isolated ? (E1000) - KS00704
Are there any objects for which Windows font cannot be used? (GOT1000) - KS02204
Windows fonts can be used for switches, lamps, panel meters, and characters of objects. Windows fonts cannot be used for other objects.
Are there enough countermeasure against static electricity for the naked base unit? Are there no problem for users to change the base unit by themselves? (GOT1000) - KS00403
There is no problem for users to handle the base unit according to instructions in the manual.
Are there limitation of components to be used for Layer function? (GOT1000) - KS00418
All components can be used for Layer function. Component (objects, figures) layering increases the freedom of design.
At which GT11 models is the GT11-50FNB board built into the standard product? (GOT1000) - KS01729
At all models with function version D or later the GT11-50FNB board is built into the standard product.
At which GT15 models is the GT15-FNB board built into the standard product? (GOT1000) - KS01727
The option function board GT15-FNB is built into the GOT version D or later. For enabling the option function board built in the GOT, the latest ..
Read moreThe option function board GT15-FNB is built into the GOT version D or later. For enabling the option function board built in the GOT, the latest standard monitor OS must be installed on the GOT.
Batteries of GT15 resemble those of PLCs'. Can the batteries be used for PLCs? (GOT1000) - KS00427
Black Line shown insted of Key fields in the panel (E1000) - KS02131
Sometimes when converting projects you will see a black line instead of the key fields in the panel. This is because the Key fields contain multi ..
Read moreSometimes when converting projects you will see a black line instead of the key fields in the panel. This is because the Key fields contain multi language indexes. Even if the corresponding Multilanguage index is empty the key field will be shown in the panel. To fix this you can go into the Show index mode and delete the entries in the key fields.
Both serial and BUS connection can be used for transparent function? (GOT1000) - KS00414
GT15: When RS232 is used to connect a personal computer to the GOT, BUS can be used to connect the GOT to the PLC in order to utilize transparent ..
Read moreGT15: When RS232 is used to connect a personal computer to the GOT, BUS can be used to connect the GOT to the PLC in order to utilize transparent function (BUS). When USB is used to connect a personal computer to the GOT, BUS can be used to connect the GOT to the PLC (transparent of BUS connection) or RS232(422) can be used to connect the GOT to the PLC (transparent of CPU direct connection). GT11: When RS232 or USB is used to connect a personal computer to the GOT, RS422(232) can be used to connect the GOT and the PLC in order to utilize transparent function. Transparent function is also valid for software packages needed for other FA-equipment (inverters, Servo amplifier etc.). Please check the manuals for details.
Cable drawing for E1000 connected to MIM-A01 Alarm Modem ( RS232 port ) (E1000) - KS00584
Cable guide (CAB1 - CAB36) (General) - KS00148
Can alarm and recipe data be saved in GT15 internal memory? (GOT1000) - KS02199
Alarm and recipe data will be saved only to CF card.
Can an FX- and an A-system, each fitted with an E series HMI and Ethernet IFC card, communicate via TCP/IP network? (MAC E Series) - KS00085
Yes. But only signals with the same type of addressing, that is T. C, D and M.
Can BMP and JPEG data be displayed on GOT directly from internal memory or CF card? (GOT1000) - KS02187
BMP and JPEG files saved to CF card can be used as components for parts display and parts movement.
Can BUS wiring diagram be disclosed? (it is preferable to create BUS cable by ourselves) (GOT1000) - KS02201
BUS wiring diagram will not be disclosed because Mitshubishi cannot provide product assurance with customers' self-produced BUS cables.
Can comment files be used directly from the CF card? (GOT1000) - KS02197
Comment files cannot be used directly from the CF card.
Can E1000 HMIs display Cyrillic/Russian system messages? (E1000) - KS01329
Yes, this is possible. If you select multiple language settings and choose 'used-defined', you can upload the existing system messages from the E1000 ..
Read moreYes, this is possible. If you select multiple language settings and choose 'used-defined', you can upload the existing system messages from the E1000 into your project. Afterwards, these texts can be translated under Setup>>>Multiple Language >>> Edit. Please see attached screenshots for mor explanation.
More information (English): ZIP (70.98 KB)
Can GOT-A900 cables be used on GOT1000 units? (GOT1000) - KS00040
Unfortunately no. Due to the new cable specifications GOT-A900 series cables cannot be utilized for GOT1000.
Can GOT1000 cables be used on GOT-A900 units? (GOT1000) - KS00041
Unfortunately no. Due to the new cable specifications for GOT1000 series they are not compatible with GOT-A900 series displays.
Can GT11 communicate with Hitachi PLC S10 series? (GOT1000) - KS00598
Yes, S10-A and S10-V are both compatible with the GT11. The Hidic and EB series are no longer in production therefore no connection tests have been ..
Read moreYes, S10-A and S10-V are both compatible with the GT11. The Hidic and EB series are no longer in production therefore no connection tests have been carried out. We can not take any responsibility for the old PLCs.
Can I change the layout of ASCII input keyboard to display for example cyrillic signs? (E1000) - KS01618
Can I connect a GT1155 via RS232 to an Allen-Bradley Micrologix 1500 CPU ? (GOT1000) - KS02640
Yes, this is possible. Please use this cable from Allen-Bradley : 1761-CBL-PM02 cable (Series C or later ).
Can I connect a Handy GOT to a Profibus network ? (GOT1000) - KS02647
No, it´s not possible to connect a Handy GOT to a profibus network. You can connect to Siemens via MPI using a CAB11 cable.
Can I connect an E1000 to Modbus Plus protocol? (E1000) - KS00162
The Modbus Plus is a higher layer of the Modbus protocol and is not compatible with the standard Modbus protocol. It use a different physical ..
Read moreThe Modbus Plus is a higher layer of the Modbus protocol and is not compatible with the standard Modbus protocol. It use a different physical connection than Modbus and can therefore not communicate on the same 'lines' There exists a converter between Modbus Plus and Modbus called BM85 (Bridge Mux) from Schneider Electric.
More information (English): JPG (53.26 KB)
Can I connect my USB printer in the front mounted USB port on the GT15? (GOT1000) - KS04011
No, the front mounted USB port is used for programming, debug and troubleshooting your system
Can I connect PCL 6 standard USB printers to E1000 terminals? (E1000) - KS02984
No, the printer class PCL 6 is not supported at all!
Can I connect two E1000 to a PPI network with S7-200 PLCs? (E1000) - KS00595
The PPI protocol supports several Masters on the network - but our driver does not support multiple masters, sorry!
Can I connect two E1151 to a System Q Ethernet module ? (E1000) - KS02646
Yes, this is possible. But maybe you have to use a switch or hub because one cable segment can only be max. 100 meters.
Can I create a static text for an E1000 with more than one line ? (E1000) - KS02690
Can I hide objects in GT15 (GOT1000) - KS01871
Yes, it is possible by using an object script. Please see attached demo-project!
Can I mount an E1000 touch terminal upside down (Rotation) by 180 degrees)? (E1000) - KS00154
Mounting E1000 touch terminals up-side-down, or in other words to rotate the screen picture 180°, can make life easier for machine builders that ..
Read moreMounting E1000 touch terminals up-side-down, or in other words to rotate the screen picture 180°, can make life easier for machine builders that have little available space and benefit from placing the cable connection in any direction they wish. This is already possible! It was first implemented as a customer specific solution, and is available in version 1.20 of E-Designer. You need to write 'FLIP' in the command line. This will rotate the whole image 180 degrees. It works in both landscape and portrait mode. Information about this feature will be included in the next version of the E-Designer Reference Manual and Help files.
Can I prevent the user from switching the E Series HMI into programming mode? (MAC E Series) - KS00108
You can enter the command RPD in the command line under Setup/System Signals (RUN/PROG DISABLE). Switches off the possibility to alternate between ..
Read moreYou can enter the command RPD in the command line under Setup/System Signals (RUN/PROG DISABLE). Switches off the possibility to alternate between RUN/PROG with the keys [BACKSPACE] and [MAIN]. If RPD is used the terminal can only alternate modes through E-Designer.
Can I print text files that are created in the E1000 directly like recipes or trend files? (E1000) - KS02151
It is not possible to print text files such as recipes and trend files that are created in the operator terminal directly from the terminal. These ..
Read moreIt is not possible to print text files such as recipes and trend files that are created in the operator terminal directly from the terminal. These files must be downloaded to the PC to be printed. Windows CE does not include any software to open text files.
Can I protect my project with a password so that it can not be loaded out of the E Series HMI without knowing the password? (MAC E Series) - KS00111
Yes, you can define a password for project transfer. On the command line under Setup/System Signals you can enter the command PDxxxxxxxx. The command ..
Read moreYes, you can define a password for project transfer. On the command line under Setup/System Signals you can enter the command PDxxxxxxxx. The command means that a password (xxxxxxxx) must be given to access the functions in the menu TRANSFER in the terminal. When transferring projects from E-Designer to the terminal this password must be given in the terminal.
Can I save recipes on external memory card in runtime? (E1000) - KS02266
Saving recipes on an external memory card can be executed by means of the function 'Saves recipe on memory card' in a function- or touchkey. The ..
Read moreSaving recipes on an external memory card can be executed by means of the function 'Saves recipe on memory card' in a function- or touchkey. The entire recipes directory in the operator panel will then be saved to the memory card.
Can I store Trand data in an E1012/E1022? (E1000) - KS02675
No, the E1000 Micro series does not support data logging!
Can I talk to two different types of PLC using Ethernet? (MAC E Series) - KS00097
Yes this is possible but you can by attaching the two drivers to the same TCP/IP connection in peripheral settings after installing the network card.
Can I use a spreadsheet to load recipes into my terminal? (GOT1000) - KS04009
Yes - it's possible to use the Import / Export function in GT-Designer2 to utilize data populated in spreadsheets.
Can I use a USB drive to load applications to my GT16 terminal? (GOT1000) - KS04017
Yes - it is possible to use a flash drive / jump drive to load projects on to a GT16 terminal. You can also take advantage of the Backup/Restore ..
Read moreYes - it is possible to use a flash drive / jump drive to load projects on to a GT16 terminal. You can also take advantage of the Backup/Restore Function.
Can I use a USB keyboard and / or mouse with the GT16? (GOT1000) - KS04018
Yes - it is possible to connect these devices to the USB device port on the front of the GT16 terminal. If both devices are required at the same ..
Read moreYes - it is possible to connect these devices to the USB device port on the front of the GT16 terminal. If both devices are required at the same time, we recommend using a USB hub to connect both of these devices.
Can I use Bus- and CC-Link-connection at the same time in Multi-channel connection of GT15? (GOT1000) - KS01903
No, only 1 channel of the GT15 can be connected to the bus- or network connection. All other connections must be serial.
Can I use Bus- and MELSECNET-connection at the same time in Multi-channel connection of GT15? (GOT1000) - KS01901
No, only 1 channel of the GT15 can be connected to the bus- or network connection. All other connections must be serial.
Can I use Bus-connection and Ethernet communication at the same time in Multi-channel connection of GT15? (GOT1000) - KS01894
No, only 1 channel of the GT15 can be connected to the bus- or network connection. All other connections must be serial.
Can I use CC-Link connection and Ethernet communication at the same time in Multi-channel connection of GT15? (GOT1000) - KS01898
No, only 1 channel of the GT15 can be connected to the bus- or network connection. All other connections must be serial.
Can I use CC-Link- and MELSECNET-communication at the same time in Multi-channel connection of GT15? (GOT1000) - KS01904
No, only 1 channel of the GT15 can be connected to the bus- or network connection. All other connections must be serial.
Can I use MELSECNET-connection and Ethernet communication at the same time in Multi-channel connection of GT15? (GOT1000) - KS01900
No, only 1 channel of the GT15 can be connected to the bus- or network connection. All other connections must be serial.
Can I use RS422 to connect a Handy GOT GT1155HS-QSBD and a S7/300 ? Libros gratis para descargar sin registrarse. (GOT1000) - KS02638
Connection between Handy GOT GT1155HS-QSBD and S7/300 over RS422 is NOT possible. Only RS 232, please see attached pdf.
Can I use special characters for recipe names? (E1000) - KS02265
No, the first character must be a letter or digit, and can only contain the characters A-Z, 0-9 and _.
Can I use the E100 Telemecanique driver to connect to Telemecanique Twido ? (MAC E Series) - KS01600
You can´t connect an E100 to a Twido using the Telemecanique driver. The Twido supports Modbus so the customer can use our Modbus Master driver to ..
Read moreYou can´t connect an E100 to a Twido using the Telemecanique driver. The Twido supports Modbus so the customer can use our Modbus Master driver to connect to the PLC-system.
Can I use the GT10-RS2TUSB-5s USB converter to program my SystemQ? (GOT1000) - KS00889
Yes. This adaptor will be connected to the 6-pin Mini-DIN programming interface of the Q-CPU. The PC connection is done using a Mini-USB Type B cable ..
Read moreYes. This adaptor will be connected to the 6-pin Mini-DIN programming interface of the Q-CPU. The PC connection is done using a Mini-USB Type B cable to an USB-Port of the PCs. Using a driver-CD which comes in the package, the converter is installed as an additional serial interface (e.g. COM6) which then can be used in any software application.
Can I use the integrated Ethernet port to communicate to other devices simultaneously? (GOT1000) - KS04023
Yes - the integrated Ethernet port can communicate to 4 different Ethernet devices simultaneously.
Can I use the project data created in GT Designer also in GT Designer2? (GOT1000) - KS01736
The project data created with GT Designer is also available in GT Designer2.
Can I use the RS232 programming port on the GT1020 for external Devices? (GOT1000) - KS00596
Unfortunately, you can only connect your PC for project up- and download.
Mitsubishi E Designer Software Online
Can I use the simulator in E-Designer also for E1012/E1022? (E1000) - KS02776
In E-Designer 7.50 an offline simulator for E1012 and E1020 was introduced to make the development process easier. This allows the project developer ..
Read moreIn E-Designer 7.50 an offline simulator for E1012 and E1020 was introduced to make the development process easier. This allows the project developer test the application without having access to the operator panel. The simulator works exactly the same as for the larger E1000 panels.
Can image data file names be used without renaming? (8+3 format or long name can be displayed? Chinese characters are not acceptable?) (GOT1000) - KS02188
Image file names should be renamed. To save BMP/JPEG file parts to memory card, save the files to IMAGE folder renaming as IMG****.BMP or ..
Read moreImage file names should be renamed. To save BMP/JPEG file parts to memory card, save the files to IMAGE folder renaming as IMG****.BMP or IMG****.JPG. (**** means 0001-0999)
Can JPEG be used? (GOT1000) - KS00435
Can printers be connected to USB port? (GOT1000) - KS02189
Printers cannot be connected to the front USB port.
Can Taiwanese (traditional Chinese) be displayed on the GOT? (GOT1000) - KS00034
Simplified Chinese can be displayed but traditional Chinese is not supported at this moment.
Can Thai be displayed? (GOT1000) - KS02195
Thai can be displayed using TrueType font. Thai cannot be used for objects for which TrueType font cannot be set. (ex: comment display)
Can the Bus-connection cable for A900-GOT be used for GOT1000? (GOT1000) - KS01739
Can the Bus-connection cable for GOT1000 be used for A900-GOT? (GOT1000) - KS01740
Can the E1000 image that is shown within VNC be modified to show the function key legends? (E1000) - KS00585
We have received this request from a few customers. Unfortunately it's not a quick fix. The information about the texts for the text strip is saved ..
Read moreWe have received this request from a few customers. Unfortunately it's not a quick fix. The information about the texts for the text strip is saved in the E-Designer project, but is not sent to the panel. Therefore changes must be made both in E-Designer and in the VNC software.So far this change has not been prioritized.
Can the GOT automatically translate my application into another language using its multi-language handling capabilities? (GOT1000) - KS04014
The GOT does not perform any language translations. In the terminal, you are simply assigning a register that can be used to index between comments ..
Read moreThe GOT does not perform any language translations. In the terminal, you are simply assigning a register that can be used to index between comments that are stored or configured in the terminal. The language or comments file can be easily exported (Unicode or CSV file) so other applications or individuals can perform the language translation.
Can the GOT be used to communicate to both the PLC function and VFD parameters of the Mitsubishi A700 VFD at the same time? (GOT1000) - KS04077
Only if using GT15 and the multi-channel function can you access both the PLC and VFD function simultaneously.
Can the GOT be used to communicate to the Mitsubishi A700 VFD? (GOT1000) - KS04015
Yes, the GOT1000 (GT15/G11/GT10) can interface to any 500/700 Series Mitsubishi VFD. Note: GT15/GT11 models supported the VFD connection in ..
Read moreYes, the GOT1000 (GT15/G11/GT10) can interface to any 500/700 Series Mitsubishi VFD. Note: GT15/GT11 models supported the VFD connection in GT-Designer2 Version 2.18 and later, GT10 supported VFD connections in GTD2 V2.73 and later revisions.
Can the GT16 Series perform MES functions? (GOT1000) - KS04024
Yes- provided that the correct optional memory board (GT16-MESB) is installed in the unit. The GT15 series option is not compatible.
Can two E-series HMIs be connected to one S7-200 PLC via PPi interface? What about S7-300 and S7-400 MPI? (MAC E Series) - KS01182
No, we do not support transparent mode neither in the S7 200 PPi nor the S7 MPI driver from Siemens.
Can two E1000-series HMIs be connected to one S7-200 PLC via PPi interface? What about S7-300 and S7-400 MPI? (E1000) - KS01183
No, we do not support transparent mode neither in the S7 200 PPi nor the S7 MPI driver from Siemens.
Can you tell me the display intensity for the E1070 ? (E1000) - KS02654
Can you tell me the display intensity for the E1071 ? (E1000) - KS02653
Can you tell me the display intensity for the E1151 ? (E1000) - KS02650
Can you tell me the display intensity of the E1100 ? (E1000) - KS02652
Can you tell me the display intensity of the E1101 ? (E1000) - KS02651
Cautions when using MELSEC-Q series and GOT-A900/GOT1000 series connected to a personal computer (General) - KS00358
Connection of a special external USB keyboard to E1000 (E1000) - KS01714
Is it possible to connect a special external USB keyboard, for example a numerical block with an ENTER key to change setpoints or a keyboard with ..
Read moreIs it possible to connect a special external USB keyboard, for example a numerical block with an ENTER key to change setpoints or a keyboard with special function keys.
The E1000-terminals support PC type keyboards (US English). The keyboard needs to support the USB Human Input Device (HID) driver (this driver is built-in WIN CE). A numerical block with an enter key will work but keyboards with special function keys will not work since these keyboards need a software to be installed on the PC/terminal (a configuration software - the 'normal' keys might work but it depends on the requirements of the keyboard). As there are many different types of external keyboards or numerical blocks we can not guarantee that your selected one will work properly!
Connection of E1000 and Siemens S7 using MPI direct (CAB36) (E1000) - KS01063
Please note that the description in the Online driver help regarding the pin assignments is NOT correct and needs to be updated. The connection of ..
Read morePlease note that the description in the Online driver help regarding the pin assignments is NOT correct and needs to be updated. The connection of the pin 0V and 5V on the PLC side are missing. Only use the CAB36 cable with Art. number 205178. Also refer to the attached drawing to prepare the cable yourself.
More information (English): PDF (36.23 KB)
Difference between vs O/S 1.30 and 1.31 for E1000 (E1000) - KS01434
What is the difference between O/S 1.30 and O/S 1.31 for the E1000 series? The main difference between 1.30 and 1.31 is that an important fix ..
Read moreWhat is the difference between O/S 1.30 and O/S 1.31 for the E1000 series? The main difference between 1.30 and 1.31 is that an important fix that was made is included in 1.31. The problem was that in terminals with heavy projects (many trends etc.) the project memory could in some cases be erased after a reboot. Most customers would not notice this problem but for customers with big project it was a major issue. There are some other small fixes as well but this is the most important one.
Do the E1000 terminals have a 'heartbeat' or 'Watchdog' signal for the communication with the PLC? (E1000) - KS02662
Yes there is, starting from firmware version 1.50 (E-Designer 7.50). The signals are the internal variables M8196 for driver 1 and M8197 for driver ..
Read moreYes there is, starting from firmware version 1.50 (E-Designer 7.50).
The signals are the internal variables M8196 for driver 1 and M8197 for driver 2.
Please see attached PDF.
More information: PDF (79.55 KB)
Do you have the electrical link drawing for the GT01-30R2-6P cable (GT11 cable connection with system Q) ? (GOT1000) - KS02221
Does GOT1000 adopt 16dot unit to valid area of touchswitch? (GOT1000) - KS00420
GOT1000 adopts digital touch panel of 16dot unit (the same as GOT-A900 series).
Does GT11 have all functions of FGOT? (GOT1000) - KS00424
GT11 initial version does not have all functions of FGOT. It is under consideration to develop remaining functions in the future.
Does the Allan Bradley CLX drive support a Compact Logix PLC on Ethernet?'. The driver help file only mentions a Control Logix PLC. (E1000) - KS02568
The CLX-driver should work just fine when connecting an E1000 to a CompactLogix.
Does the GT10 support connection the Mitsubishi MR-J3-T Servo? (GOT1000) - KS04087
Currently, the GT10 Series does not support this connection but support is expected early 2009. Until release, use GT15 or GT11 Series.
E-Designer and Windows Vista (E1000) - KS01499
We do not support Windows Vista as an operating system for E-Designer. You will have to use Windows XP instead.
Mitsubishi E Designer Software Reviews
E-series problems with transparent mode (MAC E Series) - KS00579
You should on the command line for the E-series project type in BSD (Baudrate Switch Disabled), then the terminal will use the configured baudrate.
E-View and E-Designer incompatibility (MAC E Series) - KS01289
I'm not enable to launch again my project on Eview software. I haven´t used my Eview software until 2 months. Before everything was working ..
Read moreI'm not enable to launch again my project on Eview software. I haven´t used my Eview software until 2 months. Before everything was working well. When I launch my project I have a message like that 'no licence found, start in demo mode'.
Do you have E-Designer 7.20 or higher installed ? The reason that E-view crashes when installing E-Designer is that the 2 softwares use a common file. E-Designer installs a new version of the PropertyBag.dll which is not supported by E-view. To solve this the E-view PropertyBag.dll must be in the same directory as the E-view installation. (Same directory as eview.exe) The attached zip file contains 3 files that must be in the same directory as the eview.exe. eview.exe.local PropertyBag.dll toolmgr.cfg The eview.exe.local is an empty file but will make E-view to read the PropertyBag.dll from the local directory instead of the unsupported PropertyBag.dll from the E-Designer installation.
More information: ZIP (177.98 KB)
E1000 HMI access (E1000) - KS01327
Our customer has protected his application on an E1071 with Network Accounts function for the Ethernet Up/Down load and all works fine; but he needs ..
Read moreOur customer has protected his application on an E1071 with Network Accounts function for the Ethernet Up/Down load and all works fine; but he needs to protect the HMI application also the Up/Down load via RS232C communication port, so he wrote a password in Command line. With this added function when customer tried to download the application via Ethernet connection the HMI asks for the password, but this isn't possible because the HMI E1071is in a remote place !?! Questions are: Is it possible that 'Network Accounts function' overlap the password ? -> No, this is not possible. Or is possible to disable the access via RS232C port ? -> No, this is not possible either, sorry.
E1000 Ignore com error message in Modbus Master driver (E1000) - KS01445
For Modbus Master, com errors are not displayed if 'xhce' is entered in the command line in Advanced Driver Properties.
E1000 problems with unwanted HMI reboot (E1000) - KS00586
Question: An E1000 project has some buttons to change screen, and this buttons have a level security with a password. It seems that sometimes, when ..
Read moreQuestion: An E1000 project has some buttons to change screen, and this buttons have a level security with a password. It seems that sometimes, when one of these butoons is pressed, the terminal reboots and then shows the keypad to enter the password. Solution: The problem is caused by the moving and not overlapping keyboard function in combination with a password input. The moving and not overlapping keyboard function can be switched off with the system command 'AATIO'. This prevents reboot and screen block. The bug will be corrected in the next version of the image/firmware but the quickest solution/work-around is to use the system command.
E1000 project cannot be transferred to terminal (E1000) - KS02535
An analogue numeric object prevents the project from being downloaded to the HMI, or even simulated with E-Designer.
Read moreAn analogue numeric object prevents the project from being downloaded to the HMI, or even simulated with E-Designer.
There is a known problem when having too many dynamic events on one analog numeric. If you have too many the project won’t be downloaded to the panel.